H- Ion Source RF Plasma Testing with 13.56 MHz and 27.12 MHz at the Spallation Neutron Source (SNS)

Not scheduled
20m
Victoria Conference Centre

Victoria Conference Centre

Poster (by default) Key Technologies for Ion Sources Monday

Speakers

Amith Hulikal Narayan (Oak Ridge National Laboratory) Baoxi Han (Oak Ridge National Laboratory) Robert Welton (Oak Ridge National Laboratory) Chris Stinson (Oak Ridge National Laboratory) Greg Terszakowec (Oak Ridge National Laboratory) Chip Piller (Oak Ridge National Laboratory) Vic Andzulis (Oak Ridge National Laboratory)

Description

The baseline RF-driven H- ion source configuration at the Spallation Neutron Source (SNS) facility uses a continuous wave (CW) 600 W 13.56 MHz RF system to ignite and maintain a low-intensity plasma inside the ion source vacuum chamber. After the continuous low-intensity 13.56 MHz plasma has been established, a pulsed (typical 1 ms pulse width and 60 Hz pulse repetition rate) 80 kW 2 MHz RF system is used to increase the plasma intensity for the production of the pulsed H- ion beam. Incremental upgrades and improvements to the SNS ion source systems have resulted in the ability to reliably operate an H- ion source for SNS neutron production run cycles that can last up to four months. Conditions inside the SNS H- ion source change throughout a four-month run cycle due to changes in impurity levels, sputtering, and erosion. As the internal ion source conditions change during the run cycle, there can also be changes in plasma stability and the 13.56 MHz RF power level required to ignite the plasma. This paper presents the results of testing performed on the SNS Ion Source Test Stand (ISTS) system, where we looked at plasma ignition and plasma stability for H- ion sources of different ages using 13.56 MHz RF and 27.12 MHz RF.

Funding Agency ORNL
Email Address narayana@ornl.gov
I have read the Code of Conduct to attend ICIS2023. Yes
Presenter if not the submitter of this abstract Amith Hulikal Narayan

Primary author

Amith Hulikal Narayan (Oak Ridge National Laboratory)

Co-authors

Baoxi Han (Oak Ridge National Laboratory) Robert Welton (Oak Ridge National Laboratory) Chris Stinson (Oak Ridge National Laboratory) Greg Terszakowec (Oak Ridge National Laboratory) Chip Piller (Oak Ridge National Laboratory) Vic Andzulis (Oak Ridge National Laboratory) Mr Vestal Carter Dr Yoon Kang